Адсорбционные осушители холодной регенерации RED

RED
MODEL
Connection Nominal volume flow Dimensions Mass
IN/OUT
[inch]
Inlet¹
[Nm³/h]
Outlet²
[Nm³/h]
A
[mm]
B
[mm]
C
[mm]

kg
RED 110 G1’’ 110 86 650 390 1570 126
RED 150 G1’’ 150 117,5 700 410 1820 142
RED 200 G1’’ 200 157 700 450 1600 180
RED 250 G1’’ 260 204 700 450 1850 220
RED 300 G1 1/2’’ 320 251 900 530 1620 255
RED 400 G1 1/2’’ 410 321,5 900 530 1870 275
RED 600 G1 1/2’’ 590 462,5 850 700 1940 355
RED 800 G2’’ 770 603,5 1000 710 1980 470
RED 1000 G2’’ 1000 784 1050 710 1980 560

"(¹) Refers to 1 bar(a) and 20 °C at 7 bar operating pressure , inlet temperature 35 °C and pressure dew point at outlet —40 °C

(²) Outlet flow refers to typical assumption during regeneration phase for operating at nominal inlet flow conditions. Outlet flow includes average air losses of approximately 17,3 %.

* If dryer is supplied without inlet filter compressed air class 1 (ISO 8753-1) for solid particles and oil should be provided to the inlet of the dryer.

REMARK

  • Standard dew point is —40 °C.
  • Dew points —25 °C and —70 °C on request.
  • Filter ELEMENTS should be changed at least once per year."
RED
MODEL
Connection Nominal volume flow Dimensions Mass
IN/OUT
[DN]
Inlet¹
[Nm³/h]
Outlet²
[Nm³/h]
A
[mm]
B
[mm]
C
[mm]

kg
RED 1200 DN50 1200 936 1400 600 2050 650
RED 1500 DN65 1500 1170 1500 650 2100 850
RED 2000 DN65 2000 1560 1600 750 2150 950
RED 2500 DN80 2500 1950 1750 800 2250 1100
RED 3000 DN80 3000 2340 1900 850 2250 1500
RED 3750 DN100 3750 2925 2100 950 2350 2000
RED 5000 DN100 5000 3900 2250 1050 2650 2450
RED 6500 DN125 6500 5070 2450 1100 2850 3000

"(¹) Refers to 1 bar(a) and 20 °C at 7 bar operating pressure , inlet temperature 35 °C and pressure dew point at outlet —40 °C

(²) Outlet flow refers to typical assumption during regeneration phase for operating at nominal inlet flow conditions. Outlet flow includes average air losses of approximately 17,3 %.

* If dryer is supplied without inlet filter compressed air class 1 (ISO 8753-1) for solid particles and oil should be provided to the inlet of the dryer.

REMARK

  • Standard dew point is —40 °C.
  • Dew points —25 °C and —70 °C on request.
  • Filter ELEMENTS should be changed at least once per year."